CLOSE

True Echo Explosion Proof Pulse Radar Level Transmitter

True Echo Explosion Proof Pulse Radar Level Transmitter

PRX

Dependable Level Readings In Hazardous Areas

True Echo™ PRX makes getting dependable level readings in Class I, Division 1, and Class II/III,  Division 1 hazardous locations simple.

With a low dielectric requirement for target materials, and radar’s reliable accuracy in environments with foam or vapors, the easy to install True Echo™ PRX makes getting dependable level readings in hazardous places simple.

Explosion Proof
The True Echo™ PRX Explosion Proof Pulse Radar Level Transmitter brings the unassailable level readings of radar sensors to Class I, Division 1, and Class II/III, Division 1 hazardous locations.

Easy Wiring & Set-up
From a 2- or 3-wire 4-20 mA output, to pushbutton field calibration, everything about the True Echo™ PRX is easy.

Self Adjusting
True Echo™ PRX automatically adjusts signal power for optimal accuracy and output clarity.

COMMON MODEL CONFIGURATIONS

All common model configurations can be purchased online, click the model number link below. Refer to Model Number Configurator on the datasheet for a full list of configuration options.

Model Number Model Description
PRX-050-V024-C4-AL-TE-T2 50' range, aluminum body, teflon antenna, 2" NPT mount, RS-485 communication
PRS-050-V024-C4-SS-TE-T2 50' range, 316L stainless steel body, teflon antenna, 2" NPT mount, RS-485 communication
PRS-100-V024-C4-AL-S6-T3 100' range, aluminum body, 316 L SS 6" horn, 3" NPT mount, RS-485 communication
Performance

Available Ranges
PRX-017: 1 to 17 ft.
PRX-050: 1 to 50 ft.
PRX-100: 1 to 100 ft.
Frequency
6.3 GHz
Accuracy
±0.25% of maximum range
Resolution
6.1 μA (approx. 2622 digital counts across range)
Material Dielectric
Er > 2

Physical

Housing
Aluminum
316 Stainless Steel
Mounting
1.5, 2, or 3 in. NPT
13 in. Ø 316L SS Bottom Flange
Antenna
Teflon Rod
316L Stainless Steel 6” Ø Horn
High Temperature Teflon Rod
High Temperature 316L SS Horn
High Pressure Teflon Rod

Electrical

Loop Resistance
RL = (VS - 6) / 24 mA
Input Voltage
12-30 VDC
20-35 VDC (HART)
Power Consumption
0.07 A max, 1.68 W @ 24 VDC

Environmental

Probe Operating Temperature
Standard: -40 to 176° F (-40 to 80° C)
High Temp: -40 to 350° F (-40 to 177° C)
Extreme Temp: -40 to 572° F (-40 to 300° C)
Enclosure Operating Temperature
-40 to 140° F
Maximum Process Pressure
Standard Temp/Pressure: 5 bar (72.5 psi)
Standard Temp/High Pressure: 70 bar (1015.3 psi)
High/Extreme Temps: 2 bar (29.0 psi)
Protection Rating
NEMA 4x/IP65

Approvals

FCC
Part 15 for low power communications class II install
FM Certifications
Explosion Proof
Class I Division 1 Groups B, C, D T6 (Ta 60°C)
Dust-Ignition Proof
Class II/III Division 1 Groups E, F, G T6 (Ta 60°C)

Connectivity

Output
3 wire 4-20mA
2 wire HART

Have a Question?

Our team is here to help you find the perfect solution for your needs. Contact us today!
Contact Us
Copyright © 2025 All Rights Reserved
lockenvelopephone-handsetmap-markermagnifiercrossmenu linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram