CLOSE

True Echo Dual Frequency Pulse Radar Level Transmitter For Solids

True Echo Dual Frequency Pulse Radar Level Transmitter For Solids

PRS

Dependable Level Readings From Difficult Materials

Whether powders or pellets, grains or granules, the True Echo™ PRS’s dual frequencies bring the unassailably accurate level readings of radar sensors to difficult to measure solids.

The True Echo™ PRS Dual Frequency Pulse Radar Level Transmitter For Solids brings the unassailably accurate level readings of radar sensors to difficult to measure solids. Whether powders or pellets, grains or granules, the True Echo™ PRS’s dual frequencies to allow it to quickly and accurately read the complex reflections from piled solids.
The True Echo™ also automaticaly adjusts signal power for optimal accuracy and clarity. With echo masking and
damping factors programmable via software, getting dependable level readings from difficult materials is simple.

FEATURES

  • Ranges: 17, 50, or 100 feet
  • ±0.25% of measured range accuracy
  • 6.1 μA output resolution
  • Field configurable 4-20 mA/20-4 mA Output
  • RS-232, RS-485, or HART communications
  • PC calibration, diagnostic and data logging software
  • PLC compatible (Modbus RTU)
  • Nema 6/ IP68 enclosure rating
  • Simple installation and setup
  • Automatic adjustments for most tank conditions
  • Very low material dielectric constant requirement
  • Optional Fast Firmware for quickly changing levels

DATASHEETS & DOWNLOADS

PRS

Performance

Operating Range:
PRS-017: 1 -17 ft. (0.3 - 5 m)
PRS-050: 1 - 50 ft. (0.3 - 15 m)
PRS-100: 1 - 100 ft. (0.3 - 30 m)
Frequency: 
6.3 GHz and 26 GHz
Accuracy:
± 0.25% of maximum range
4-20 mA Resolution:
6.1 μA (approx. 2622 digital counts across range)
Target Dielectric Constant:
εr > 2

Physical

Antenna
Horn: 316L Stainless Steel, Ø 6.3” (160 mm)
Beam spread: 3° from center

Electrical

Loop Resistance:
RL = (VS - 6) / 24 mA
Input Voltage:
12-30 VDC; 20-35 VDC (HART);
115 VAC (60 Hz); 230 VAC (50 Hz)
Power Consumption:
0.07 A max,  1.68 W @ 24 VDC
1.7 VA for 115/230 VAC

Environmental

Enclosure Operating Temperature:
-40º to 140ºF (-40 to 60ºC)
Process/Probe Temperatures:
Standard   -40º to 176ºF (-40 to 80ºC)
High Temp  -40º to 350ºF (-40 to 177ºC)
Extreme Temp  -40º to 572ºF (-40 to 300ºC)
Maximum Process Pressures:
Standard Temp  5 bar (72.5 psi)
High/Extreme Temps 2 bar (29.0 psi)
Enclosure:
NEMA 6: Aluminum or 316L Stainless Steel, IP68 Sealing

Approvals

Certifications
FCC  Part 15 for low power communications class II install

Connectivity

Output:
4-20 mA (shared common or isolated); HART

Have a Question?

Our team is here to help you find the perfect solution for your needs. Contact us today!
Contact Us
Copyright © 2024 All Rights Reserved
lockenvelopephone-handsetmap-markermagnifiercrossmenu linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram