Flexible Magnetostrictive Float Level Transmitter

MPX-F

Extra Flexibility For Your Extra-Long Measurements

The MPX-F Flexible Magnetostrictive Float Level Transmitter is designed for easy installation in tall tanks, featuring flexible 316L stainless steel tubing with a braided stem. This innovative design simplifies installation, making it a reliable solution for liquid level measurement in chemical processing, water treatment, oil and gas industries, and more. The MPX-F offers high performance with Modbus RTU output for seamless integration into existing systems, ensuring accurate readings and easy monitoring.

  • Superior Flexibility: The 316L stainless steel flexible tubing coils for shipping and uncoils easily for quick installation in tall tanks without the need for heavy equipment.
  • Modbus Output: RS-485 Modbus RTU output ensures compatibility with Modbus controllers and PLCs, streamlining integration and setup.
  • Remote Monitoring: Supports monitoring for real-time remote access to tank levels, ideal for large-scale industrial applications.
  • Durability: Corrosion-resistant 316L SS tubing and reliable performance in challenging environments.
  • Cost-Effective: Reduces installation and maintenance costs by eliminating the need for cranes and simplifying wiring.

  • Resolution:
    • 4-20 mA: 14 bit DAC (1 mm)
    • Modbus: 0.04 in. (1 mm)
  • Distance Accuracy:
    • 4-20 mA, Modbus: Greater of +/- 0.05% of FS or 1 mm
  • Temperature Accuracy:
    • RTD—1K Ohm: ± 1°C
    • Digital Temp Sensor: ± 1°C
  • Operating Temperature: -40°–185° F (-40°–85° C)
  • IP65
  • Electrical Connection: Terminal Block, 12-24 VDC
  • Typical Current Draw:
    • 4-20 mA: (single) 4-22 mA, (dual) 8-44 mA
    • Modbus (RS-485): 28 mA
  • Reverse polarity protection: Yes
  • Surge protection: Output 4 only
  • RS-485: Optional RST-6001 USB to RS-485 converter
  • 4-20 mA: Factory set or optional RST-4100 programming module
  • Output:
    • Single or dual loop-powered 4-20 mA
      • Set points:
      • 4 mA, probe bottom.
      • 20 mA 10 in. below probe zero point or at customer specified point
    • Modbus RTU (RS-485), optional temperature output
  • Housing: Cast aluminum, epoxy coated
  • Stem: 7/8” Ø 316L SS Flexible Tubing with Braid
  • Stem Length: 10–32 ft. (1.22–9.75 m)
  • CSA:
    • Rated 12–24 VDC; 4-20 mA or 80 mA; Ta 85°C
      • Class I, Division 2, Groups C & D T4
      • Ex nA IIB T4
      • Class I, Zone 2; AEx nA IIB T4
What makes the MPX-F different from other level transmitters?

The MPX-F features flexible 316L stainless steel tubing with a braided stem, allowing for easy installation in tall tanks without heavy equipment. Its Modbus RTU output ensures seamless integration into existing systems, while its corrosion-resistant design ensures durability in harsh environments.

Unlike rigid level transmitters, the MPX-F’s flexible tubing can be coiled for shipping and easily uncoiled for installation, reducing the need for cranes or large lifting equipment. This significantly lowers installation costs and effort.

The MPX-F is ideal for chemical processing, water treatment, oil and gas, and food and beverage industries. It provides accurate tank level monitoring and remote access, making it suitable for a wide range of industrial applications.

Yes, the MPX-F supports remote monitoring by providing real-time data when connected to SETTLER and Explorer. This feature is especially useful for large-scale industrial applications that require continuous oversight of tank levels.

Yes, the MPX-F is constructed with corrosion-resistant 316L stainless steel tubing, ensuring long-lasting performance even in challenging environments such as chemical processing plants and wastewater treatment facilities.

Increase the sensitivity settings on your sensor.

Here are the steps to get the sensor communication back as sensor #1 using the APG Modbus software and the RST-6001 (USB to RS485 converter). 

It’s essentially the same process below to establish communication. 

 

Establishing Communication:

  1. On the APG Modbus software, go to Configure>Communication.
  2. Make sure the USB box is checked; the Sensor Type is MPX-1/4 RS485 and the Sensor# ID is showing 1.
  3. Click Save Configuration and then click Save.
  4. Click on the Green “Start Communication” Button.

After communication has been established, use the second procedure to change the sensor address. 

 

Changing the Sensor Address:

  1. Change Register 400 from 1 to the desired address number.
  2. Click Send. At this point, you will see a Comm Bad. That’s ok, go to Step 3.
  3. Click again on Configure>Communication.
  4. Change the Sensor ID from 1 to the new address number.
  5. Click Save Configuration and then click Save.
  6. Click on the Green “Start Communication” Button.

Your MPX probe should be communicating to the software with its new address. 

MOUNT

Flange, No Mount, NPT

OUTPUT

4-20 mA, Modbus

PROBE LENGTH

10' – 31.5'

CERTIFICATION

CSA – General, Explosion Proof

ENCLOSURE PROTECTION

IP65

INDUSTRY